This site needs JavaScript to work properly. Please enable it to take advantage of the complete set of features!
Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Save citation to file

Add to Collections

Name must be less than 100 characters
Unable to load your collection due to an error
Please try again

Add to My Bibliography

Unable to load your delegates due to an error
Please try again

Your saved search

Would you like email updates of new search results?
Saved Search Alert Radio Buttons
()

Create a file for external citation management software

Your RSS Feed

. 1988 Jun 16;318(24):1572-8.
doi: 10.1056/NEJM198806163182404.

Bedside diagnosis of systolic murmurs

Affiliations

Affiliation

  • 1 Department of Medicine, University of Texas Health Science Center at San Antonio.

Bedside diagnosis of systolic murmurs

N J Lembo et al. N Engl J Med. .
. 1988 Jun 16;318(24):1572-8.
doi: 10.1056/NEJM198806163182404.

Affiliation

  • 1 Department of Medicine, University of Texas Health Science Center at San Antonio.

Abstract

The diagnostic accuracy of bedside maneuvers in the evaluation of patients with systolic murmurs has not been assessed objectively. Therefore, we evaluated 50 patients with documented systolic murmurs and compared all standard bedside techniques. Murmurs originating within the right-sided chambers of the heart were best differentiated from all other murmurs by augmentation of their intensity with inspiration (100 percent sensitivity, 88 percent specificity) and diminution of their intensity with expiration (100 percent sensitivity, 88 percent specificity). The murmur of hypertrophic cardiomyopathy was distinguished from all other murmurs by an increase in intensity with the Valsalva maneuver (65 percent sensitivity, 96 percent specificity) and during squatting-to-standing action (95 percent sensitivity, 84 percent specificity), and by a decrease in intensity during standing-to-squatting action (95 percent sensitivity, 85 percent specificity), passive leg elevation (85 percent sensitivity, 91 percent specificity), and handgrip (85 percent sensitivity, 75 percent specificity). The murmurs of mitral regurgitation and ventricular septal defect had parallel responses to all maneuvers, but could be differentiated from other systolic murmurs by augmentation of their intensity with handgrip (68 percent sensitivity, 92 percent specificity) and during transient arterial occlusion (78 percent sensitivity, 100 percent specificity), and by a decrease in their intensity during the inhalation of amyl nitrite (80 percent sensitivity, 90 percent specificity). No single maneuver identified the murmur of aortic stenosis, but the diagnosis could be made by exclusion. Although no single maneuver is 100 percent accurate in diagnosing the cause of a systolic murmur, its origin can be determined accurately at the bedside by observation of the response to a combination of maneuvers.

PubMed Disclaimer

Publication types

LinkOut - more resources

Cite
Morty Proxy This is a proxified and sanitized view of the page, visit original site.