This site needs JavaScript to work properly. Please enable it to take advantage of the complete set of features!
Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Save citation to file

Add to Collections

Name must be less than 100 characters
Unable to load your collection due to an error
Please try again

Add to My Bibliography

Unable to load your delegates due to an error
Please try again

Your saved search

Would you like email updates of new search results?
Saved Search Alert Radio Buttons
()

Create a file for external citation management software

Your RSS Feed

Review
. 1999 Jan;50(1):215-36.
doi: 10.1016/s0969-8043(98)00026-8.

Radiation exposure in bone mineral density assessment

Affiliations

Affiliation

  • 1 Department of Radiology, University of California, San Francisco, USA.
Review

Radiation exposure in bone mineral density assessment

C F Njeh et al. Appl Radiat Isot. 1999 Jan.
. 1999 Jan;50(1):215-36.
doi: 10.1016/s0969-8043(98)00026-8.

Affiliation

  • 1 Department of Radiology, University of California, San Francisco, USA.

Abstract

Osteoporosis is a systematic skeletal disease characterized by low bone mass and microarchitectural deterioration of bone tissue which leads to diminished biomechanical competence of the skeleton and low-trauma or atraumatic fractures. Due to increased awareness of the impact of osteoporosis on the elderly population, the use of bone densitometric techniques is becoming more widespread. Considerable progress has been made in the development of non-invasive methods for the assessment of the skeleton. While DXA and QCT are commonly used techniques, the popularity of other approaches such as RA, SXA and QUS is gaining grounds. QCT has an advantage over the other techniques in its ability to measure the true volumetric density of trabecular or cortical bone. We therefore present an overview of these current techniques for bone mineral density (BMD) measurements. In the second section we discuss the radiation doses incurred in BMD measurements by patients and methods for reducing patient and staff radiation exposure are given. Studies of radiation dose to patient from DXA confirms that patient dose is small (0.08-4.6 muSv) compared to that given by many other investigations involving ionizing radiation. Fan beam technology with increased resolution has resulted in increase patient dose radiation dose (6.7-31 muSv) but this is still relatively small. Carrying vertebral morphometry using DXA also incurs less radiation dose (< 60 muSv) than standard lateral radiographs QCT has radiation dose (25-360 muSv) comparable to simple radiological examination such as chest X-ray but lower than imaging CT. Radiation dose from other techniques such as RA and SXA are in the same order of magnitude as pencil beam DXA. For pencil beam DXA and SXA systems the time average dose to staff from scatter is very low even with the operator sitting as close as 1 m from the patient during measurement. However the scatter dose from fan beam DXA systems is considerable higher and approaches limits set by regulator bodies for occupational exposure.

PubMed Disclaimer

LinkOut - more resources

Cite
Morty Proxy This is a proxified and sanitized view of the page, visit original site.